STANDARD(S) :
IEC 60855-1 / IEC 61235-S

USE : All-weather (last IEC 60855-1 tube extended).
- Checking for the absence of voltage.
- Earthing of MV/LV substations
- Disconnector operation.
- All work involving medium mechanical loads.
The TR poles come in 4 ranges:
• TR: Classic
• TRS: Special - foam-filled tube, orange end section, Ø 32 mm, quality IEC 60855-1
• TRL: Lightweight - foam-filled tube, yellow end section, Ø 26 mm, 30% lighter than the TR Classic (NB: medium load acceptable up to 5 m, beyond that use only for no-voltage testing and disconnector operation)
• TRC: Shock-resistant: tubes with greater shock-resistance properties.

SPECIFICATIONS :
• Made up of 2, 3 or 4 sections:
- upper tube foam-filled fibreglass composite, Ø 32 mm or Ø 26 mm, quality IEC 60855-1, colour yellow or orange,
- intermediate and lower tubes made of yellow fibreglass composite, Ø 48, 39 or 32 mm, quality IEC 61235-S,
• Push-button mechanism for locking into retracted or extended position,
• Base with protected connector for optional extension (on some TR2 models, see table of references).
• Dielectric strength after wet conditioning:
- 100 kV/30 cm upper sections
- 50 kV/30cm lower sections
TR poles can be supplied off the shelf with these end fittings :
- APV : multi-purpose, 12 mm 6-sided with automatic locking.
- U : notched universal end fitting.
- B : bayonet end fitting.
- EAF : multi-purpose, 21 mm 6-sided.
- Others : on request, please enquire

EXTENSION AVAILABLE FOR STICKS TR275 / TRS275 / TR2225 / TR2245 / TR2330.

TABLE LEGEND :
Complete the reference of your choice with the code corresponding to the end fitting required: APV, U, B or EAF. The operating voltages correspond to the minimum insulation length requirements of IEC 61243-1 for no-voltage testing.

TRL2070 / 0,40(kg) / TRL type insulating telescopic pole 2 elements / Cover H1P060V /Type TRL / Number of elements 2 / Fully folded length (m) 0,43 / Max voltage of use - all weather Indoor use only / Fully extended length (m) 0,70 / Maximum operating voltage - dry weather 36 kV
TRL2092 / 0,42(kg) / TRL type insulating telescopic pole 2 elements / Cover H1P060V /Type TRL / Number of elements 2 / Fully folded length (m) 0,55 / Max voltage of use - all weather Indoor use only / Fully extended length (m) 0,92 / Maximum operating voltage - dry weather 72 kV
TRL2105 / 0,43(kg) / TRL type insulating telescopic pole 2 elements / Cover H1P080V /Type TRL / Number of elements 2 / Fully folded length (m) 0,61 / Max voltage of use - all weather Indoor use only / Fully extended length (m) 1,05 / Maximum operating voltage - dry weather 72 kV
TRL2150 / 0,84(kg) / TRL type insulating telescopic pole 2 elements / Cover HTR1950 /Type TRL / Number of elements 2 / Fully folded length (m) 0,83 / Max voltage of use - all weather 36 kV / Fully extended length (m) 1,50 / Maximum operating voltage - dry weather 72 kV
TRL2250 / 1,05(kg) / TRL type insulating telescopic pole 2 elements / Cover - /Type TRL / Number of elements 2 / Fully folded length (m) 1,33 / Max voltage of use - all weather 123 kV / Fully extended length (m) 2,50 / Maximum operating voltage - dry weather 170 kV
TRL2300 / 1,35(kg) / TRL type insulating telescopic pole 2 elements / Cover - /Type TRL / Number of elements 2 / Fully folded length (m) 1,58 / Max voltage of use - all weather 123 kV / Fully extended length (m) 3,00 / Maximum operating voltage - dry weather 170 kV
TRL2340 / 1,65(kg) / TRL type insulating telescopic pole 2 elements / Cover - /Type TRL / Number of elements 2 / Fully folded length (m) 1,78 / Max voltage of use - all weather 170 kV / Fully extended length (m) 3,40 / Maximum operating voltage - dry weather 245 kV
TRL2400 / 2,00(kg) / TRL type insulating telescopic pole 2 elements / Cover - /Type TRL / Number of elements 2 / Fully folded length (m) 2,08 / Max voltage of use - all weather 170 kV / Fully extended length (m) 4,00 / Maximum operating voltage - dry weather 245 kV
TRL3150 / 0,89(kg) / TRL type insulating telescopic pole 3 elements / Cover H1P080V /Type TRL / Number of elements 3 / Fully folded length (m) 0,64 / Max voltage of use - all weather 25 kV / Fully extended length (m) 1,50 / Maximum operating voltage - dry weather 63 kV
TRL3250 / 1,47(kg) / TRL type insulating telescopic pole 3 elements / Cover H1P120V /Type TRL / Number of elements 3 / Fully folded length (m) 1,09 / Max voltage of use - all weather 72 kV / Fully extended length (m) 2,50 / Maximum operating voltage - dry weather 123 kV
TRL3450 / 2,20(kg) / TRL type insulating telescopic pole 3 elements / Cover - /Type TRL / Number of elements 3 / Fully folded length (m) 1,76 / Max voltage of use - all weather 123 kV / Fully extended length (m) 4,50 / Maximum operating voltage - dry weather 245 kV
TRL3500 / 2,45(kg) / TRL type insulating telescopic pole 3 elements / Cover - /Type TRL / Number of elements 3 / Fully folded length (m) 1,93 / Max voltage of use - all weather 170 kV / Fully extended length (m) 5,00 / Maximum operating voltage - dry weather 420 kV
TRL3600 / 3,20(kg) / TRL type insulating telescopic pole 3 elements / Cover - /Type TRL / Number of elements 3 / Fully folded length (m) 2,27 / Max voltage of use - all weather 170 kV / Fully extended length (m) 6,00 / Maximum operating voltage - dry weather 525 kV
TRL4400 / 3,60(kg) / TRL type insulating telescopic pole 4 elements / Cover - /Type TRL / Number of elements 4 / Fully folded length (m) 1,37 / Max voltage of use - all weather 72 kV / Fully extended length (m) 4,00 / Maximum operating voltage - dry weather 245 kV
TRL4500 / 4,20(kg) / TRL type insulating telescopic pole 4 elements / Cover - /Type TRL / Number of elements 4 / Fully folded length (m) 1,62 / Max voltage of use - all weather 123 kV / Fully extended length (m) 5,00 / Maximum operating voltage - dry weather 420 kV
TRL4600 / 4,70(kg) / TRL type insulating telescopic pole 4 elements / Cover - /Type TRL / Number of elements 4 / Fully folded length (m) 1,87 / Max voltage of use - all weather 123 kV / Fully extended length (m) 6,00 / Maximum operating voltage - dry weather 420 kV

0,00 € 0.0 EUR 0,00 €

Not Available For Sale

8 people are viewing this right now

This combination does not exist.

PENTA ESP (Electrical Safety Products)
PENTA ESP (Electrical Safety Products)

Multinational industrial leader, pioneer, and expert manufacturer of electrical safety solutions, committed to ensuring your safety at every intervention.

PROTECT - We offer you individual and collective protective equipment essential to personal health and safety.
SECURE - We manufacture equipment specifically adapted to your networks to guarantee a safe worksite for everyone involved.
WORK - We deliver high-performance tools that enable you to carry out your technical work safely and efficiently.
SERVICES - We provide you with our manufacturer-expert response: audit/advice, R&D, training, technical assistance, operational maintenance, customisation, or equipment hire, etc.
SOLUTIONS - We design complete solutions (products and dedicated services) for your LV, MV and HV operations, whether live or dead. Our sustainable achievements have become a benchmark for professional users worldwide.

Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days