TRL Telescopic sticks

STANDARD(S) :
IEC 60855-1 / IEC 61235-S

USE : All-weather (last IEC 60855-1 tube extended).
- Checking for the absence of voltage.
- Earthing of MV/LV substations
- Disconnector operation.
- All work involving medium mechanical loads.
The TR poles come in 4 ranges:
• TR: Classic
• TRS: Special - foam-filled tube, orange end section, Ø 32 mm, quality IEC 60855-1
• TRL: Lightweight - foam-filled tube, yellow end section, Ø 26 mm, 30% lighter than the TR Classic (NB: medium load acceptable up to 5 m, beyond that use only for no-voltage testing and disconnector operation)
• TRC: Shock-resistant: tubes with greater shock-resistance properties.

SPECIFICATIONS :
• Made up of 2, 3 or 4 sections:
- upper tube foam-filled fibreglass composite, Ø 32 mm or Ø 26 mm, quality IEC 60855-1, colour yellow or orange,
- intermediate and lower tubes made of yellow fibreglass composite, Ø 48, 39 or 32 mm, quality IEC 61235-S,
• Push-button mechanism for locking into retracted or extended position,
• Base with protected connector for optional extension (on some TR2 models, see table of references).
• Dielectric strength after wet conditioning:
- 100 kV/30 cm upper sections
- 50 kV/30cm lower sections
TR poles can be supplied off the shelf with these end fittings :
- APV : multi-purpose, 12 mm 6-sided with automatic locking.
- U : notched universal end fitting.
- B : bayonet end fitting.
- EAF : multi-purpose, 21 mm 6-sided.
- Others : on request, please enquire

EXTENSION AVAILABLE FOR STICKS TR275 / TRS275 / TR2225 / TR2245 / TR2330.

TABLE LEGEND :
Complete the reference of your choice with the code corresponding to the end fitting required: APV, U, B or EAF. The operating voltages correspond to the minimum insulation length requirements of IEC 61243-1 for no-voltage testing.

TRL2070 = Cover: H1P060V , Number of elements: 2 , Fully folded length (m): 0.43 , Fully extended length (m): 0.7 , Max. operating voltage - dry weather: 36 kV , Max. operating voltage - all weather: Indoor use only , Weight (kg): 0.4
TRL3150 = Cover: H1P080V , Number of elements: 3 , Fully folded length (m): 0.64 , Fully extended length (m): 1.5 , Max. operating voltage - dry weather: 63 kV , Max. operating voltage - all weather: 25 kV , Weight (kg): 0.89
TRL3250 = Cover: H1P120V , Number of elements: 3 , Fully folded length (m): 1.09 , Fully extended length (m): 2.5 , Max. operating voltage - dry weather: 123 kV , Max. operating voltage - all weather: 72 kV , Weight (kg): 1.47
TRL2092 = Cover: H1P060V , Number of elements: 2 , Fully folded length (m): 0.55 , Fully extended length (m): 0.92 , Max. operating voltage - dry weather: 72 kV , Max. operating voltage - all weather: Indoor use only , Weight (kg): 0.42
TRL2105 = Cover: H1P080V , Number of elements: 2 , Fully folded length (m): 0.61 , Fully extended length (m): 1.05 , Max. operating voltage - dry weather: 72 kV , Max. operating voltage - all weather: Indoor use only , Weight (kg): 0.43
TRL2150 = Cover: HTR1950 , Number of elements: 2 , Fully folded length (m): 0.83 , Fully extended length (m): 1.5 , Max. operating voltage - dry weather: 72 kV , Max. operating voltage - all weather: 36 kV , Weight (kg): 0.84
TRL3450 , Number of elements: 3 , Fully folded length (m): 1.76 , Fully extended length (m): 4.5 , Max. operating voltage - dry weather: 245 kV , Max. operating voltage - all weather: 123 kV , Weight (kg): 2.2
TRL3600 , Number of elements: 3 , Fully folded length (m): 2.27 , Fully extended length (m): 6 , Max. operating voltage - dry weather: 525 kV , Max. operating voltage - all weather: 170 kV , Weight (kg): 3.2
TRL2250 , Number of elements: 2 , Fully folded length (m): 1.33 , Fully extended length (m): 2.5 , Max. operating voltage - dry weather: 170 kV , Max. operating voltage - all weather: 123 kV , Weight (kg): 1.05
TRL2300 , Number of elements: 2 , Fully folded length (m): 1.58 , Fully extended length (m): 3 , Max. operating voltage - dry weather: 170 kV , Max. operating voltage - all weather: 123 kV , Weight (kg): 1.35
TRL2340 , Number of elements: 2 , Fully folded length (m): 1.78 , Fully extended length (m): 3.4 , Max. operating voltage - dry weather: 245 kV , Max. operating voltage - all weather: 170 kV , Weight (kg): 1.65
TRL2400 , Number of elements: 2 , Fully folded length (m): 2.08 , Fully extended length (m): 4 , Max. operating voltage - dry weather: 245 kV , Max. operating voltage - all weather: 170 kV , Weight (kg): 2
TRL4400 , Number of elements: 4 , Fully folded length (m): 1.37 , Fully extended length (m): 4 , Max. operating voltage - dry weather: 245 kV , Max. operating voltage - all weather: 72 kV , Weight (kg): 3.6
TRL4500 , Number of elements: 4 , Fully folded length (m): 1.62 , Fully extended length (m): 5 , Max. operating voltage - dry weather: 420 kV , Max. operating voltage - all weather: 123 kV , Weight (kg): 4.2
TRL4600 , Number of elements: 4 , Fully folded length (m): 1.87 , Fully extended length (m): 6 , Max. operating voltage - dry weather: 420 kV , Max. operating voltage - all weather: 123 kV , Weight (kg): 4.7

0.00 € 0.0 EUR 0.00 €

1.00 Lek


    This combination does not exist.

    Add to Cart Buy Now

    PENTA ESP (Electrical Safety Products)
    PENTA ESP (Electrical Safety Products)

    We are PENTA 🚀 👷🏽‍♀️ Multinational industrial leader, pioneer and expert manufacturer of electrical safety solutions, committed to ensuring your safety at every intervention! 🤝 We are the essential partner for linemen, maintenance technicians and electricians working on power generation, transmission and distribution networks all over the world, and in 9 other areas of activity. With over 1200 employees in 18 subsidiaries worldwide, PENTA adapts its products to all electrical standards and regulations of each country. You will find our electrical safety solutions under different brands.


    Best Value 
    Fast Delivery
    Quality Consistency

    Share this product:
    This is a preview of the recently viewed products by the user.
    Once the user has seen at least one product this snippet will be visible.
    Recently viewed Products